According to Central Building Research Institute, what is the specification adopted for the floor of single and double-story buildings?
Try it first: pick an option, then read the explanation.
Understanding Concrete Floor Specifications
A standard concrete ground floor is typically constructed in two main layers: a base course and a wearing course (or topping). This two-layer system is designed for stability, durability, and cost-effectiveness. The specifications for mix ratios (cement : fine aggregate : coarse aggregate) and thickness are crucial for the floor's performance.
CBRI (Central Building Research Institute): This is a premier research institute in India that provides scientifically-backed guidelines and specifications for various construction practices to ensure quality, safety, and economy.
Detailed Analysis of the Options
Let's break down the CBRI specification and see why the other options are not ideal.
(a) & (d) Incorrect Topping Mix/Thickness
Why they are incorrect: A 1:3:5 mix is a very lean concrete mix, generally not suitable for a floor's wearing surface, which needs to be strong and abrasion-resistant. While thicknesses of 30mm or 40mm are plausible, the mix ratio is the primary issue, as it would lead to a weaker surface that could wear out quickly under foot traffic.
(c) Incorrect Topping Mix
Why it's incorrect: A 1:4:6 concrete mix is even leaner than 1:3:5 and is typically used for mass concrete works or as a base where strength is not a primary concern. Using this for a floor topping would result in a very poor, porous, and weak surface that is completely unsuitable for any kind of flooring.
(b) Correct Specification
Why it IS the correct specification: This option correctly identifies the two-layer system recommended by CBRI:
- Base Course: 11.5 cm thick cement concrete with a lean mix of 1:5:10. This layer provides a stable, level base over the compacted earth. A lean mix is sufficient and economical for this purpose.
- Wearing Course (Topping): 38 mm (approx. 1.5 inches) thick cement concrete with a richer, stronger mix of 1:2:4. This provides a hard, durable, and dense surface that can withstand abrasion and daily use.
Summary of the Two-Layer Floor System
The CBRI specification follows a logical and efficient engineering practice:
- Use a lean, economical mix (1:5:10) for the thicker base course, where high strength is not required.
- Use a rich, durable mix (1:2:4) for the thinner top layer, which is exposed to wear and tear. This ensures a long-lasting floor without the unnecessary cost of using a rich mix for the entire thickness.