As per IS 10262:2019, what is the approximate amount of entrapped air expected in normal (non-air-entrained) concrete when 10 mm nominal maximum size of aggregate is used? (in %)
Try it first: pick an option, then read the explanation.
Correct answer: D. 1.5
Entrapped Air in Concrete (IS 10262:2019)
IS 10262:2019 specifies the approximate percentage of entrapped air expected in non-air-entrained concrete for each nominal maximum aggregate size. These values are used in the absolute-volume method of mix design.
IS 10262:2019 values to memorise:
10 mm aggregate → 1.5% entrapped air
20 mm aggregate → 1.0% entrapped air
40 mm aggregate → 0.8% entrapped air
10 mm aggregate → 1.5% entrapped air
20 mm aggregate → 1.0% entrapped air
40 mm aggregate → 0.8% entrapped air
For 10 mm nominal maximum aggregate size, the entrapped air is 1.5% — option D.
Key takeaway
Smaller aggregate means more surface area and more potential for trapped air. Entrapped air decreases as aggregate size increases: 1.5 → 1.0 → 0.8% for 10 → 20 → 40 mm.