Engineering Materials·MCQ explained

To prevent segregation, the maximum permissible height for placing concrete is:

Try it first: pick an option, then read the explanation.

Correct answer: C. 150 cm

Detailed Explanation: Maximum Placement Height 150 cm (IS 456:2000)

Why C (150 cm) is correct: IS 456:2000 Clause 13.2 specifies that concrete shall not be dropped from a height exceeding 1.5 m (150 cm) to prevent segregation. Beyond this height, the impact energy separates heavier coarse aggregates from the mortar, destroying the homogeneity of the mix.

Why Height Causes Segregation

Drop HeightWhat HappensOutcome
≤150 cmConcrete falls with moderate energy; stays togetherNo segregation; concrete remains homogeneous
>150 cmHigh kinetic energy on impact; aggregate bounces and separatesCoarse aggregate separated from mortar; segregation

Methods to Place Concrete Without Exceeding 150 cm

SituationSolution
Deep columns or wallsUse a tremie pipe, elephant trunk, or chute to guide concrete to the bottom
Deep foundationsTremie pipe method; concrete placed at the bottom and displaces water/soil upward
High-rise slabsPump concrete directly to the placement point at each level
General placingUse elephant trunk hose; lower the drop height at all times
  • Maximum placement height: 150 cm (1.5 m) per IS 456:2000 to prevent segregation.
  • Use tremie pipes or elephant trunks when placement depth exceeds 1.5 m.
  • Concrete placed from too great a height also loses entrained air, affecting durability.