Surveying·MCQ explained

What is the correct sequence of the temporary adjustment of a level instrument at a new field station?

Try it first: pick an option, then read the explanation.

Correct answer: C. Setting, centering and leveling

Detailed Explanation: Correct Sequence of Temporary Adjustment = Setting, Centering, Levelling

Why C (Setting, centering and levelling) is correct: Temporary adjustments are performed every time the instrument is set up at a new station. The logical sequence is: (1) set up the tripod, (2) centre the instrument over the station mark, (3) level the instrument so the bubble is central.

Sequence of Temporary Adjustments

StepActionPurpose
1. Setting upPlant the tripod firmly over the station; attach the instrument to the tribrachEstablishes a stable base at the correct location
2. CenteringAdjust the tripod legs and/or use the optical plummet to position the instrument exactly over the ground station markEnsures the instrument's vertical axis passes through the station point
3. LevellingUse foot screws (and the plate bubble or circular bubble) to make the vertical axis truly verticalEnsures horizontal plane of rotation and level line of sight
4. Focussing (elimination of parallax)Focus eyepiece to see cross hairs sharply; focus objective lens for a clear staff imageRemoves apparent cross hair movement relative to staff when eye is moved
Memory Aid: “SCLaF” — Setting, Centering, Levelling, and Focussing. The first three are the “temporary adjustments”; focussing is done before each observation.
  • Correct sequence: Setting up → Centering → Levelling (+ focussing before each reading).
  • Centering must precede levelling: levelling the instrument can shift the plummet slightly, so centering is re-checked after.