In a linear reservoir, the storage is proportional to:
Try it first: pick an option, then read the explanation.
Detailed Explanation: Linear Reservoir Storage–Discharge Relationship
A linear reservoir is a conceptual hydrological model used in rainfall-runoff analysis. The defining characteristic is a linear (directly proportional) relationship between storage and outflow. This is one of the foundational relationships in flood routing and unit hydrograph theory.
Definition of a linear reservoir:A reservoir is called linear when its storage S is directly proportional to its outflow discharge Q:
S = k × Q
where k is the storage constant (units of time). This single equation defines the linear reservoir model. There is no power term — the relationship is simply S ∝ Q (i.e., proportional to Q to the power 1, not Q² or √Q).
Why the Other Options Are Wrong
| Option | Corresponding reservoir model | Why it is not a linear reservoir |
|---|---|---|
| A — Q² | Quadratic or non-linear reservoir | S = k·Q² describes a non-linear reservoir; this applies in some surface flow models where stage-discharge follows a power curve, but it is not the linear reservoir definition |
| C — √Q | Fractional-power non-linear reservoir | S ∝ Q&sup0;·&sup5; is another non-linear relationship; not the linear reservoir model |
| D — Q³ | Cubic non-linear reservoir | S ∝ Q³ has no standard hydrological application; used nowhere in classical reservoir routing theory |
Application in Unit Hydrograph Theory
The linear reservoir concept underpins several important hydrological methods:
Nash cascade model: The catchment is represented as a cascade of n identical linear reservoirs in series, each with storage constant k. The instantaneous unit hydrograph (IUH) of this cascade follows a gamma distribution. The peak and time-to-peak are determined by n and k.
Clark's method: Uses a linear reservoir at the end of a time-area routing procedure to account for storage attenuation in a catchment.
Muskingum routing: While not strictly a linear reservoir, it uses a related storage equation S = k[xI + (1-x)Q] where x is a weighting factor. When x = 0, this reduces to S = kQ — the pure linear reservoir.
Key Concepts for Students
- S = kQ is the defining equation — memorise it exactly: The linear reservoir model is fully defined by this one equation. k has units of time (hours or days), and it represents the mean residence time of water in the reservoir. All other storage models with S ∝ Q² or S ∝ Qn (n ≠ 1) are non-linear reservoirs.
- Linear reservoir vs. level pool routing: Level pool (modified Puls) routing uses a non-linear relationship between storage and outflow (because outflow through a spillway or orifice depends on head, which gives S ∝ Q or S ∝ Q1/2 depending on structure type). The linear reservoir is a simpler conceptual model used mainly in unit hydrograph derivation and flood estimation, not in reservoir flood routing.
- Continuity equation links S, I, and Q: For any reservoir (linear or not), the governing equation is dS/dt = I − Q (inflow minus outflow = rate of storage change). For a linear reservoir, substituting S = kQ gives k(dQ/dt) = I − Q, which is a first-order linear ODE. Its solution for a given inflow pulse is an exponential response — the basis of Nash's IUH.