Geotechnical·MCQ explained

The A-line in the unified classification system table is used to determine the plasticity index (IP) of soil sample on its liquid limit (WL). The equation for the A-line is given as:

Try it first: pick an option, then read the explanation.

Correct answer: D. IP = 0.73(WL - 20)

Detailed Explanation

The A-line is the single most-used formula across this entire topic — it's the dividing line on the plasticity chart that separates clay-like behaviour from silt-like behaviour, given as a fixed linear equation.

Why "Ip = 0.73(WL - 20)" Is Correct

The A-line's equation is IP = 0.73(WL − 20), expressing the plasticity index as a linear function of the liquid limit. Soils plotting above this line (higher IP than the line predicts) are classified as clay; soils plotting below it are classified as silt.

Why the Other Options Are Wrong

  • Ip = WL - 40: not the A-line equation at all — this describes a different, steeper, unshifted line with no basis in the actual plasticity chart.
  • Ip = 0.5(20 - WL): wrong slope (0.5 instead of 0.73) and would give a negative IP for any WL above 20 — physically nonsensical, since plasticity index cannot be negative.
  • Ip = 0.73(40 - WL): has the correct slope (0.73) but the wrong sign/structure inside the parentheses — this would give a decreasing (and eventually negative) IP as WL increases, the opposite of the real A-line's behaviour.

Key Point

Ip = 0.73(WL − 20) — worth memorizing exactly, in this exact form, since scrambled-formula distractors like these are a very common exam trick.

Key Concepts for Students

  • This is the identical A-line formula used numerically in Q3, Q11, and (as a plain calculation) in Index Properties Q2.
  • The A-line only applies for WL ≥ 20% — see Index Properties Q2's Key Concepts for the caveat about the horizontal Ip = 0 boundary used below that.
  • Soils plot ABOVE the A-line (higher IP) as clay; soils plot BELOW it (lower IP) as silt — see Q3 and Q11 for this comparison applied to real numbers.
  • The plasticity chart, and its A-line, is credited to Arthur Casagrande (see Q20) — the same person behind the liquid limit apparatus and the overall Unified Soil Classification System.

Going Deeper: The Plasticity Chart: Where the A-Line Fits

The plasticity chart is the single graphical tool that decides the M/C (silt/clay) secondary symbol for fine-grained soils, and it's built around the A-line as its primary dividing boundary.

On the chart, liquid limit (WL) is plotted on the X-axis and plasticity index (IP) on the Y-axis. Every fine-grained soil sample becomes a single point on this chart, once its liquid limit and plastic limit have been measured. The A-line (IP = 0.73(WL − 20)) splits the chart into a clay region (above) and a silt/organic region (below); a second boundary, WL = 50, splits it into low-compressibility (left) and high-compressibility (right) halves.

Chart RegionSymbolMeaning
Above A-line, WL > 50CHClay, high compressibility
Above A-line, lower WLCI / CLClay, intermediate / low compressibility
Below A-line, WL > 50MH (or OH if organic)Silt, high compressibility
Below A-line, lower WLMI / ML (or OI / OL if organic)Silt, intermediate / low compressibility

Note that the Indian Standard splits the "lower liquid limit" side into two further bands (Low and Intermediate), not just one — see Q11's Going Deeper section for why, and Q16 for the complete 18-group count this three-tier system produces. Only the WL > 50 → High boundary is confirmed by an explicit numeric threshold in these questions (used directly in Q11's calculation).

This is the same core split worked through numerically in Q11 (landing on CH) — every fine-grained USCS symbol ultimately comes from locating a single (WL, IP) point on this one chart.