If 90% of soil particles got retained over 2 mm sieve and 50% of soil particles got retained over 4.75 mm sieve, then the effective diameter of the soil will be:
Try it first: pick an option, then read the explanation.
Detailed Explanation
This is the same effective-size concept as Q1 and Q33, but worked from retained (not finer) percentages directly, which is a common alternate way sieve data gets presented.
Given: 90% of particles retained on the 2 mm sieve; 50% of particles retained on the 4.75 mm sieve.
Why "2 mm" Is Correct
If 90% of the sample is retained on the 2 mm sieve, then the remaining 10% must be finer than 2 mm — which is exactly the definition of D10. So the effective size (D10) = 2 mm.
Why the Other Options Are Wrong
- 1.25 mm: not derivable from either given data point directly — no percentage corresponds to this value.
- 4.75 mm: 50% is retained on this sieve, meaning 50% is finer — that makes this D50 (the median size), not D10.
- 6.75 mm: simply the sum of the two given sieve sizes (2 + 4.75) — a distractor with no actual grain-size meaning.
Key Point
"% retained" and "% finer" are complements of each other (they sum to 100%) — always convert explicitly to % finer before identifying a D-value, rather than trying to read D10 directly off a retained percentage.
Key Concepts for Students
- 90% retained ⇒ 10% finer is the exact same conversion used in Q35's more elaborate multi-sieve problem.
- This question only needs the 2 mm data point — the 4.75 mm / 50%-retained data point is a distractor for this specific question, though it would be needed to also find D50.
- See Q1 for the same D10 concept built from a full percent-finer table rather than two isolated data points.
- Effective size (D10) is used directly in permeability estimates (via Hazen's formula, a well-known but not always tested relationship) and in the Cu/Cc gradation calculations covered in Q22-26.
Going Deeper: Reading Sieve Analysis Data: Retained vs. Cumulative vs. Finer
Sieve analysis results can be presented in several equivalent forms, and converting cleanly between them is a core skill this whole topic depends on:
| Quantity | Meaning | How to Get It |
|---|---|---|
| % Retained (on one sieve) | Fraction of the total sample caught on that specific sieve | Mass retained on that sieve ÷ total sample mass × 100 |
| Cumulative % Retained | Fraction of the sample retained on that sieve AND all coarser sieves above it | Running sum of % retained, sieve by sieve, from coarsest downward |
| % Finer (passing) | Fraction of the sample finer than that sieve size | 100% − Cumulative % Retained |
Any D-value (D10, D30, D60, or any other DXX) is always read off the % Finer column — it is the particle size at which the % Finer value equals XX%. When a question gives you "% retained on a single sieve" instead of a full table (as in this question), the fastest path is often to recognize that a single given retained percentage directly tells you its complementary finer percentage, without needing to build out a full cumulative table at all.