Geotechnical·MCQ explained

Which of the following is a method used in a field to determine the permeability of soil?

Try it first: pick an option, then read the explanation.

Correct answer: D. Pumping out of well method

Detailed Explanation

Permeability testing methods split cleanly into laboratory methods (testing a sample under controlled conditions) and field methods (testing the soil in its natural, in-situ state) — this question asks specifically for a FIELD method.

Why "Pumping out of well method" Is Correct

The pumping-out-of-well method is a field technique for determining an overall coefficient of permeability across a large area of soil, by pumping water from a well and observing the resulting drawdown in nearby observation wells. It's genuinely conducted in the field, unlike the other three options here.

FIELD PUMPING TEST (drawdown)Aquiferoriginal water tablePumping wellObs. well 1 (r1)Obs. well 2 (r2)

Pumping from a well lowers the water table into a drawdown cone; observation wells at known radii (r1, r2) record the reduced water levels (h1, h2), letting K be back-calculated from the steady-state discharge.

Why the Other Options Are Wrong

  • Falling head permeameter method: a laboratory method (see Q3, Q5) — performed on a small sample in a controlled apparatus, not in the field.
  • Oedometer test: a laboratory consolidation test apparatus, used to determine compressibility parameters (and, indirectly, permeability via Q15's consolidation-based method) — not itself a field permeability method.
  • Constant head permeameter method: also a laboratory method (see Q5, Q9) — like the falling head method, performed on a controlled sample, not in the field.

Key Point

Falling head, constant head, and oedometer-based methods are all LABORATORY techniques; pumping-out and pumping-in tests are the FIELD techniques — this lab/field split is tested from multiple angles across Q9, Q15, and this question.

Key Concepts for Students

  • Field methods give an "overall" or "average" permeability across a large, naturally-occurring soil mass, which can differ meaningfully from a small lab sample's result (see Q29).
  • See Q20 and Q21 for two fully worked numeric examples of well-pumping field tests (unconfined and confined aquifers respectively).
  • The oedometer test is more closely associated with the separate Soil Consolidation topic, though it does connect to permeability indirectly (see Q15's Cv/mv-based method).
  • See the Going Deeper section for the complete laboratory-vs-field method breakdown.

Going Deeper: Laboratory Methods vs. Field Methods, Side by Side

Choosing between a laboratory and a field method for permeability determination is a genuine engineering decision, trading off cost/speed against representativeness.

Laboratory MethodBasis
Constant head permeameterHigh-permeability soils (gravel, sand)
Falling (variable) head permeameterLow-permeability soils (silt, clay)
Capillarity-permeability testIndirect, capillary-based estimate
Indirect from consolidation testFine-grained soils, via Cv and mv
Field MethodBasis
Pumping-out testOverall permeability of a large aquifer/soil deposit
Pumping-in testLocalized permeability near a borehole

Laboratory tests are fast, cheap, and repeatable, but test only a small sample that may not capture larger-scale features like fissures, layering, or macro-structure that can dominate a real soil deposit's actual permeability. Field tests (pumping-out, pumping-in) test a much larger, naturally-occurring volume of soil directly, giving results that better represent a full-scale aquifer or excavation's actual behaviour — at the cost of being significantly more time-consuming and expensive to conduct.