Which of the following is a method used in a field to determine the permeability of soil?
Try it first: pick an option, then read the explanation.
Detailed Explanation
Permeability testing methods split cleanly into laboratory methods (testing a sample under controlled conditions) and field methods (testing the soil in its natural, in-situ state) — this question asks specifically for a FIELD method.
Why "Pumping out of well method" Is Correct
The pumping-out-of-well method is a field technique for determining an overall coefficient of permeability across a large area of soil, by pumping water from a well and observing the resulting drawdown in nearby observation wells. It's genuinely conducted in the field, unlike the other three options here.
Pumping from a well lowers the water table into a drawdown cone; observation wells at known radii (r1, r2) record the reduced water levels (h1, h2), letting K be back-calculated from the steady-state discharge.
Why the Other Options Are Wrong
- Falling head permeameter method: a laboratory method (see Q3, Q5) — performed on a small sample in a controlled apparatus, not in the field.
- Oedometer test: a laboratory consolidation test apparatus, used to determine compressibility parameters (and, indirectly, permeability via Q15's consolidation-based method) — not itself a field permeability method.
- Constant head permeameter method: also a laboratory method (see Q5, Q9) — like the falling head method, performed on a controlled sample, not in the field.
Key Point
Falling head, constant head, and oedometer-based methods are all LABORATORY techniques; pumping-out and pumping-in tests are the FIELD techniques — this lab/field split is tested from multiple angles across Q9, Q15, and this question.
Key Concepts for Students
- Field methods give an "overall" or "average" permeability across a large, naturally-occurring soil mass, which can differ meaningfully from a small lab sample's result (see Q29).
- See Q20 and Q21 for two fully worked numeric examples of well-pumping field tests (unconfined and confined aquifers respectively).
- The oedometer test is more closely associated with the separate Soil Consolidation topic, though it does connect to permeability indirectly (see Q15's Cv/mv-based method).
- See the Going Deeper section for the complete laboratory-vs-field method breakdown.
Going Deeper: Laboratory Methods vs. Field Methods, Side by Side
Choosing between a laboratory and a field method for permeability determination is a genuine engineering decision, trading off cost/speed against representativeness.
| Laboratory Method | Basis |
|---|---|
| Constant head permeameter | High-permeability soils (gravel, sand) |
| Falling (variable) head permeameter | Low-permeability soils (silt, clay) |
| Capillarity-permeability test | Indirect, capillary-based estimate |
| Indirect from consolidation test | Fine-grained soils, via Cv and mv |
| Field Method | Basis |
|---|---|
| Pumping-out test | Overall permeability of a large aquifer/soil deposit |
| Pumping-in test | Localized permeability near a borehole |
Laboratory tests are fast, cheap, and repeatable, but test only a small sample that may not capture larger-scale features like fissures, layering, or macro-structure that can dominate a real soil deposit's actual permeability. Field tests (pumping-out, pumping-in) test a much larger, naturally-occurring volume of soil directly, giving results that better represent a full-scale aquifer or excavation's actual behaviour — at the cost of being significantly more time-consuming and expensive to conduct.