Geotechnical·MCQ explained

10 m thick confined aquifer gives the steady state discharge of 0.03 m³/s through the well of 50 cm radius. Due to pumping the height of water in the well is dropped from 15 m to 10 m and the radius of influence is obtained as 500 m. What is the coefficient of permeability (mm/s)?

Try it first: pick an option, then read the explanation.

Correct answer: A. 0.66

Detailed Explanation

This is the CONFINED-aquifer counterpart to Q20's unconfined example — using the simpler, linear-drawdown discharge formula appropriate for a confined aquifer of fixed thickness.

Given: aquifer thickness D = 10 m; discharge Q = 0.03 m³/s; well radius Rw = 0.5 m; radius of influence R = 500 m; drawdown Sw = 15 − 10 = 5 m.

Formula: Q = 2πKD·Sw / ln(R/Rw)

Rearranging for K: K = Q·ln(R/Rw) / (2πD·Sw) = 0.03 × ln(1000) / (2π × 10 × 5) = 0.03 × 6.907 / 314.159 ≈ 6.59×10⁻⁴ m/s

Why "0.66" Is Correct

Converting 6.59×10⁻⁴ m/s to mm/s gives 0.659 mm/s, which rounds to 0.66 mm/s — matching option (a).

Why the Other Options Are Wrong

  • 0.99: doesn't match the correct rearranged calculation — likely from a slip in computing ln(R/Rw) or the denominator's 2πDSw term.
  • 1.25: also doesn't match — a plausible result of swapping which values go in the numerator vs. denominator of the rearranged K formula.
  • 6.89: off by roughly a factor of 10 from the correct value — likely a units conversion slip (m/s to mm/s involves a factor of 1000, not 10, and this distractor suggests an incomplete conversion).

Key Point

R/Rw = 500/0.5 = 1000 is a clean, convenient ratio here — ln(1000) ≈ 6.907 is worth recognizing directly rather than recalculating from scratch each time it appears.

Key Concepts for Students

  • This confined-aquifer formula uses a simple linear drawdown (Sw = 5 m here), unlike the unconfined-aquifer formula's squared-head terms (see Q20).
  • Aquifer thickness D stays constant in the confined-aquifer formula, since the confining layers fix the flow cross-section regardless of how much drawdown occurs.
  • Always double-check unit conversions carefully at the end (m/s → mm/s is a factor of 1000) — this is exactly where two of this question's distractors originate.
  • See Q20's Going Deeper section for the full side-by-side comparison of confined vs. unconfined aquifer discharge formulas.

Going Deeper: Radius of Influence and the Logarithmic Drawdown Curve

Both the confined and unconfined well-pumping formulas share a common feature: the radial distance term appears inside a logarithm, not linearly. This reflects the physical shape of the drawdown cone around a pumped well.

As water flows radially inward toward a pumping well, the flow must pass through progressively smaller circular cross-sections (2πrD for a confined aquifer of thickness D) as it approaches the well. Since velocity must increase as the cross-sectional area shrinks (to maintain the same total discharge), and head loss accumulates as this velocity increases, the resulting drawdown profile — the shape of the depression in the water table or piezometric surface around the well — naturally takes a logarithmic form with distance from the well. The "radius of influence" (R in this question) represents the practical distance beyond which pumping has a negligible effect on the water level.