Falling head permeability test is carried out on a soil specimen having cross-sectional area of 60 sq. cm. and height of 15 cm. The water level in the stand pipe of diametre of 0.5 cm drops from 100 cm to 40 cm in half an hour. What is the coefficient of permeability (cm/s)?
Try it first: pick an option, then read the explanation.
Detailed Explanation
This is another fully worked falling-head test calculation (see Q3, Q22), applying the exact same standard formula to a new set of given values.
Given: specimen cross-sectional area A = 60 cm², length L = 15 cm; stand-pipe diameter 0.5 cm; time t = 30 min = 1800 sec; h1 = 100 cm, h2 = 40 cm.
Step 1 — Stand-pipe area: a = πd²/4 = π(0.5)²/4 = 0.196 cm²
Step 2 — Apply the falling head formula: K = 2.303 × (a·L)/(A·t) × log₁₀(h1/h2)
K = 2.303 × (0.196 × 15)/(60 × 1800) × log₁₀(100/40) = 2.303 × (2.94/108000) × 0.3979 ≈ 2.49×10⁻⁵ cm/s
Why "2.49 × 10⁻⁵" Is Correct
Substituting all given values into the falling-head formula, with the stand-pipe area computed from its given diameter, gives K ≈ 2.49×10⁻⁵ cm/s.
Why the Other Options Are Wrong
- 2.50 × 10⁻³: off by roughly a factor of 100 — likely from a decimal-point slip in computing the stand-pipe area (πd²/4) or in the final multiplication.
- 3.38 × 10⁻⁴: doesn't match the correct calculation — could result from using the stand-pipe DIAMETER directly in the area formula rather than correctly squaring it and dividing by 4.
- 5.09 × 10⁻⁵: roughly double the correct value — a plausible result of a factor-of-2 slip somewhere in the area or log-ratio calculation.
Key Point
This is now the THIRD falling-head problem worked through in this topic (Q3, Q22, this one) — by now, the formula K = 2.303(aL/At)log10(h1/h2) and its unit-careful application should feel fully automatic.
Key Concepts for Students
- Always compute the stand-pipe area (a) from its given DIAMETER using a = πd²/4 — a common setup error is using the diameter value directly as though it were the area.
- This problem's numbers work out to a clean log₁₀(100/40) = log₁₀(2.5) ≈ 0.3979 — recognizing common logarithm values speeds up repeated falling-head calculations.
- See Q3 for the first fully worked falling-head example in this topic, and Q22 for one where the computed answer notably doesn't match any given option.
- See Q3's Going Deeper section for the complete formula comparison between falling head and constant head methods.
Going Deeper: Common Falling-Head Calculation Pitfalls
Having now worked through three separate falling-head problems in this topic (Q3, Q22, and this one), it's worth consolidating the specific places these calculations most commonly go wrong:
| Pitfall | How to Avoid It |
|---|---|
| Using stand-pipe diameter instead of area | Always compute a = πd²/4 explicitly from the given diameter before using it in the formula |
| Mixing units (cm vs. mm, hours vs. seconds) | Convert every given value to one consistent unit system before substituting into the formula |
| Forgetting the 2.303 conversion factor | This factor converts natural log to log base 10 (2.303 ≈ ln(10)) — required since the formula is written with log10, not ln |
| Swapping h1 and h2 | h1 is always the LARGER, initial head; h2 is always the SMALLER, later head — log10(h1/h2) should always come out positive |
Systematically writing out every given value with its correctly converted units (as done in the worked steps above) before touching the formula is the single most reliable habit for avoiding all four of these pitfalls at once.