In a falling head test, the initial head level is 100 cm and the head level after 100 seconds is 10 cm. The area of cross-section of stand-pipe is 10 cm², and the area of cross-section of soil sample is 100 cm². Find the permeability of soil sample if the length of sample is 20 cm.
Try it first: pick an option, then read the explanation.
Detailed Explanation
The falling head test is used specifically for low-permeability soils (see Q5), where a constant-head setup would produce an immeasurably slow, hard-to-read flow rate. Instead, it tracks how quickly the water level in a narrow stand-pipe falls over a measured time interval.
Given: area of stand-pipe a = 10 cm²; area of soil sample A = 100 cm²; length of sample L = 20 cm; time t = 100 sec; initial head h1 = 100 cm; final head h2 = 10 cm.
Formula: K = 2.303 · (a·L)/(A·t) · log10(h1/h2)
K = 2.303 × (10 × 20)/(100 × 100) × log₁₀(100/10) = 2.303 × 0.02 × 1 = 0.04606 cm/s
Why "0.046 cm/s" Is Correct
Substituting all given values into the falling-head formula gives K ≈ 0.04606 cm/s, which rounds to 0.046 cm/s.
Water level in the narrow stand-pipe (area a) falls from h1 to h2 over time t, driving flow through the soil sample (area A, length L). K = 2.303(aL/At)·log10(h1/h2).
Why the Other Options Are Wrong
- 4.6 cm/s: off by a factor of 100 — a likely decimal-point error in converting or combining the area ratio (a·L)/(A·t).
- 2.3 cm/s: close to the constant 2.303 itself, suggesting this distractor comes from forgetting to multiply by the (a·L)/(A·t) factor entirely.
- 0.023 cm/s: roughly half the correct value — could result from a factor-of-2 slip somewhere in the area or length terms.
Key Point
The falling-head formula's log₁₀(h1/h2) term uses base-10 log with the 2.303 conversion factor built in (2.303 ≈ ln(10)) — using natural log directly without this factor would give a very different (wrong) result.
Key Concepts for Students
- log₁₀(100/10) = log₁₀(10) = 1 exactly — a clean number that simplifies this particular calculation nicely.
- The stand-pipe area (a) is deliberately much smaller than the soil sample area (A), so that even a slow flow rate produces a clearly measurable, relatively quick drop in the narrow stand-pipe's water level.
- See Q22 and Q24 for two more fully worked falling-head calculations using this exact same formula.
- See Q5 for why the falling head method specifically suits low-permeability soils like silt and clay, in contrast to the constant head method used for sand and gravel.
Going Deeper: Falling Head vs. Constant Head: Full Comparison
These are the two standard laboratory methods for determining K, and choosing between them correctly is tested repeatedly throughout this topic (Q5, Q9, Q15, Q18).
| Method | Formula | Best Suited For |
|---|---|---|
| Constant head | K = QL/(Aht) | High-permeability soils (gravel, sand) — flow rate is large enough to measure directly and steadily |
| Falling (variable) head | K = 2.303(aL/At)·log10(h1/h2) | Low-permeability soils (silt, clay) — flow is too slow to measure as a steady rate, but a measurable head drop still accumulates over time |
Both formulas share the same core structure — a geometry factor (areas and length) multiplied by a driving-head term — but the falling head formula additionally accounts for the head itself continuously changing during the test, which is why it needs the logarithmic h1/h2 term rather than a single constant h.