Geotechnical·MCQ explained

The constant head permeability test is used for

Try it first: pick an option, then read the explanation.

Correct answer: C. coarse grained soil

Detailed Explanation

This is the direct counterpart to Q5: rather than asking which test suits LOW-permeability soils, this question asks which one suits HIGH-permeability soils.

Why "coarse grained soil" Is Correct

The constant head permeability test is used for soils with high permeability, such as gravel and coarse-grained soil — its steady, measurable flow rate works well precisely because these soils allow water through quickly and consistently.

Why the Other Options Are Wrong

  • organic soil: not the defining criterion for choosing between constant and falling head — the choice depends on permeability magnitude, not organic content specifically.
  • fine grained soil: the OPPOSITE case — fine-grained soils (silt, clay) call for the falling head test instead (see Q5), since they're too impermeable for a constant-head setup to measure practically.
  • clayey soil: also the opposite case — clay is a classic low-permeability soil suited to the falling head test, not the constant head test.

Key Point

Constant head test ⇄ high-permeability (coarse-grained) soils; Falling head test ⇄ low-permeability (fine-grained) soils — this single pairing appears from both directions across Q5, Q9, Q15, and Q18.

Key Concepts for Students

  • The constant head formula, K = QL/(Aht), directly uses a steady discharge rate Q — practical to measure only when flow is fast enough to collect and time accurately.
  • See Q5's Going Deeper section for the complete side-by-side comparison of both lab methods' formulas and use cases.
  • The source material for this question notes a known typo in some older printed materials, where the constant-head formula is sometimes mistakenly shown with a falling-head-style structure — always double check which formula matches the METHOD actually being described, not just which formula looks familiar.
  • See Q18 and Q29 for the separate family of FIELD methods (pumping tests), used when even a large lab sample isn't representative enough.

Going Deeper: Why Coarse-Grained Soil Suits the Constant Head Method

The constant head test maintains a fixed head difference across the soil sample and measures the volume of water Q collected over a timed interval — a method that only works well when that collected volume is large enough to measure accurately within a reasonable time.

Coarse-grained soils (sand, gravel) have large, well-connected pore spaces, allowing water to pass through quickly even under a modest head difference. This makes a steady-state, constant-head arrangement both easy to set up and quick to yield an accurate discharge measurement. By contrast, attempting this same method on clay would mean waiting an impractically long time to collect even a small, hard-to-measure volume of water — exactly the scenario the falling head test (Q5) is designed to handle instead.