The slump test is performed to check the –

The slump test is performed to check the –

A. Presence of water in cement
B. Ratio of concrete ingredients
C. Temperature resistance
D. Workability of concrete
Correct Answer: D. Workability of concrete

📚 Detailed Explanation: Purpose of the Slump Test

Why D (Workability) is correct: The slump test is the most widely used field test for workability of fresh concrete. It is quick, inexpensive, and requires minimal equipment. Option A (presence of water in cement) is checked by the Vicat needle test. Option B (ratio of ingredients) is confirmed by mix design records and batch weighing. Option C (temperature resistance) is not tested on fresh concrete — it would require fired refractory tests.

Common Fresh Concrete Tests and Their Purpose

Test Purpose
Slump test Workability (medium workability range)
Compaction factor test Workability (low workability range)
Vee-Bee test Workability (very low workability)
Flow table test Workability (very high, SCC)
Vicat needle test Setting time of cement paste
  • Slump test = workability test for medium-range mixes (25–150 mm slump).
  • Best suited for site control of concrete batches; not suitable for very stiff or very fluid mixes.

← Back to MCQs on Workability of Concrete