Surveying·MCQ explained

Following are some errors associated with a total station survey work: Vertical collimation error, Centering error, Horizontal collimation error, Eccentricity error. Categorize the given errors as those due to temporary adjustments (T) and permanent adjustments (P).

Try it first: pick an option, then read the explanation.

Correct answer: D. T: Centering error | P: Vertical collimation error, Horizontal collimation error, Eccentricity error

Detailed Explanation: Temporary vs. Permanent Adjustment Errors

Errors in total station/theodolite work fall into two broad categories based on when and how they arise: temporary adjustment errors (made fresh at every single field setup) and permanent adjustment errors (built into the instrument's calibration, persisting until the instrument is re-adjusted in a workshop or via on-board calibration).

Why centring alone is temporary, and the rest are permanent:
Centering is performed afresh at every single station setup — the surveyor must re-position the instrument over the ground mark every time it is moved, making it inherently a temporary adjustment error.

Vertical collimation, horizontal collimation, and eccentricity errors are all properties of the instrument's internal calibration — the alignment of its optical/mechanical components relative to its axes. These do not change from setup to setup; they persist across the whole survey until the instrument is recalibrated. This makes all three permanent adjustment errors.

Error Classification Table

ErrorCategoryWhy
Centering errorTemporary (T)Re-done at every new station setup; depends on operator care each time
Vertical collimation errorPermanent (P)Relates to internal axis alignment of the instrument, fixed until recalibrated
Horizontal collimation errorPermanent (P)Relates to internal axis alignment of the instrument, fixed until recalibrated
Eccentricity errorPermanent (P)Arises from manufacturing/assembly offset between circle centre and rotation axis; constant for the instrument

Why the Other Options Are Wrong

A, B, C: Each of these options places at least one of the three genuinely permanent errors (vertical collimation, horizontal collimation, eccentricity) into the temporary category, or vice versa, misclassifying instrument-calibration properties as setup-dependent ones (or the reverse).

Key Concepts for Students

  • Ask "does this reset at every new setup?": If yes, it is temporary (centring, levelling, focusing/parallax). If no — if it is a fixed property of the instrument's internal geometry — it is permanent (collimation, eccentricity, axis perpendicularity).
  • Permanent errors require workshop/calibration correction: Unlike temporary errors which the field surveyor corrects every time through setup procedure, permanent errors require specific adjustment screws or factory/service calibration to fix.
  • Face-left/face-right averaging targets permanent errors: Many permanent errors (collimation, eccentricity) can be effectively cancelled in the field by averaging face-left and face-right observations, without needing to physically re-adjust the instrument — a key field workaround.