Following are some errors associated with a total station survey work: Vertical collimation error, Centering error, Horizontal collimation error, Eccentricity error. Categorize the given errors as those due to temporary adjustments (T) and permanent adjustments (P).
Try it first: pick an option, then read the explanation.
Detailed Explanation: Temporary vs. Permanent Adjustment Errors
Errors in total station/theodolite work fall into two broad categories based on when and how they arise: temporary adjustment errors (made fresh at every single field setup) and permanent adjustment errors (built into the instrument's calibration, persisting until the instrument is re-adjusted in a workshop or via on-board calibration).
Why centring alone is temporary, and the rest are permanent:Centering is performed afresh at every single station setup — the surveyor must re-position the instrument over the ground mark every time it is moved, making it inherently a temporary adjustment error.
Vertical collimation, horizontal collimation, and eccentricity errors are all properties of the instrument's internal calibration — the alignment of its optical/mechanical components relative to its axes. These do not change from setup to setup; they persist across the whole survey until the instrument is recalibrated. This makes all three permanent adjustment errors.
Error Classification Table
| Error | Category | Why |
|---|---|---|
| Centering error | Temporary (T) | Re-done at every new station setup; depends on operator care each time |
| Vertical collimation error | Permanent (P) | Relates to internal axis alignment of the instrument, fixed until recalibrated |
| Horizontal collimation error | Permanent (P) | Relates to internal axis alignment of the instrument, fixed until recalibrated |
| Eccentricity error | Permanent (P) | Arises from manufacturing/assembly offset between circle centre and rotation axis; constant for the instrument |
Why the Other Options Are Wrong
A, B, C: Each of these options places at least one of the three genuinely permanent errors (vertical collimation, horizontal collimation, eccentricity) into the temporary category, or vice versa, misclassifying instrument-calibration properties as setup-dependent ones (or the reverse).
Key Concepts for Students
- Ask "does this reset at every new setup?": If yes, it is temporary (centring, levelling, focusing/parallax). If no — if it is a fixed property of the instrument's internal geometry — it is permanent (collimation, eccentricity, axis perpendicularity).
- Permanent errors require workshop/calibration correction: Unlike temporary errors which the field surveyor corrects every time through setup procedure, permanent errors require specific adjustment screws or factory/service calibration to fix.
- Face-left/face-right averaging targets permanent errors: Many permanent errors (collimation, eccentricity) can be effectively cancelled in the field by averaging face-left and face-right observations, without needing to physically re-adjust the instrument — a key field workaround.