Surveying·MCQ explained

While using a theodolite, how to change the reading on the horizontal circle while measuring a horizontal angle?

Try it first: pick an option, then read the explanation.

Correct answer: C. Upper clamp is loosened and lower clamp is tightened

Detailed Explanation: Changing the Horizontal Circle Reading

This question is a direct, practical application of the double-axis clamp system explained in Q12. Setting a new horizontal circle reading (e.g., zeroing the instrument or setting an initial reading) is one of the most fundamental field operations.

Why lower clamp tight + upper clamp loose changes the circle reading:
As established in Q12, the lower plate (carrying the main graduated circle) sits on the outer spindle, and the upper plate (carrying the vernier/index) sits on the inner spindle. With the lower clamp tightened, the graduated circle stays perfectly fixed. With the upper clamp loosened, the vernier (on the upper plate) is free to rotate relative to that fixed circle. Rotating the upper plate in this state changes the vernier reading against the stationary graduated circle — exactly what is needed to set a desired horizontal angle reading before beginning observations.

Why the Other Options Are Wrong

A — Both clamps tight: With both spindles locked, no rotation at all is possible, so the reading cannot be changed in this state.

B — Upper tight, lower loose: This is the "lower motion" configuration (see Q12's key concepts) — with the upper clamp tight, the vernier is fixed relative to the upper plate; loosening the lower clamp instead allows both plates (circle and vernier together) to rotate as a unit, preserving the angle already set between them rather than changing it.

D — Both clamps loose: With neither spindle locked, the instrument could spin freely in an uncontrolled way, with no defined relative motion to reliably set a specific reading.

Key Concepts for Students

  • "Upper motion" sets/changes the angle reading itself: Lower clamp tight (graduated circle fixed) + upper clamp loose (vernier free) is the standard configuration used to dial in a specific starting horizontal circle reading, such as setting it to exactly 0°00'00" before beginning a round of angles.
  • "Lower motion" re-points without disturbing the set angle: Upper clamp tight + lower clamp loose lets the surveyor swing the entire instrument to re-sight a different reference object while preserving whatever angle reading was already established — useful when re-orienting between rounds.
  • Practical field sequence: To begin a traverse leg with a 0° back-sight reading: loosen the upper clamp (lower clamp tight), rotate the telescope to sight the back station, set the vernier to read exactly 0°, then tighten the upper clamp again before swinging to the foresight using lower motion.