If the void ratio and discharge velocity for soil is 0.5 and 6 × 10⁻7 m/s respectively, what is the value of seepage velocity (m/s)?
Try it first: pick an option, then read the explanation.
Detailed Explanation
Discharge velocity (the Darcy velocity used throughout most of this topic) and seepage velocity (the actual average velocity of water moving through the pore spaces themselves) are related but numerically different quantities.
Given: void ratio e = 0.5; discharge velocity V = 6×10⁻⁷ m/s.
Step 1 — Porosity: n = e/(1+e) = 0.5/1.5 = 1/3
Step 2 — Seepage velocity: V = n × Vs ⇒ Vs = V/n = (6×10⁻⁷)/(1/3) = 18×10⁻⁷ m/s
Why "18 × 10⁻⁷" Is Correct
Since discharge velocity relates to seepage velocity via V = n·Vs, dividing the given discharge velocity by the computed porosity (1/3) gives Vs = 18×10⁻⁷ m/s.
Why the Other Options Are Wrong
- 3 × 10⁻⁷: roughly half the discharge velocity rather than a multiple of it — doesn't match the V = n·Vs relationship, which requires DIVIDING by porosity (a fraction less than 1), which always increases the value, not decreases it.
- 6 × 10⁻⁷: this is simply the given discharge velocity itself, unchanged — mistakenly treating seepage velocity as identical to discharge velocity, ignoring the porosity correction entirely.
- 12 × 10⁻⁷: close to, but not matching, the correct value — possibly from using porosity = 0.5 directly (i.e., confusing porosity with void ratio) rather than correctly computing n = e/(1+e) = 1/3 first.
Key Point
Seepage velocity is always GREATER than discharge velocity (since porosity n is always less than 1, dividing by it always increases the value) — water moving through only the pore spaces must move faster than the average "as if it filled the whole cross-section" discharge velocity, to carry the same total flow.
Key Concepts for Students
- Discharge (Darcy) velocity assumes flow spreads evenly across the ENTIRE cross-sectional area of the soil, including the solid particles; seepage velocity accounts for the fact that water can only actually move through the void space.
- V = n·Vs is the standard relationship connecting the two — always convert void ratio to porosity first (n = e/(1+e)) before applying it.
- This distinction matters practically for contaminant transport problems, where the ACTUAL travel time of a pollutant through soil depends on the (faster) seepage velocity, not the (slower) discharge velocity.
- A void ratio of 0.5 giving a porosity of exactly 1/3 is a clean, easily-remembered benchmark conversion.
Going Deeper: Discharge Velocity vs. Seepage Velocity
Darcy's law (v = K·i) technically gives the DISCHARGE velocity — a somewhat artificial quantity representing the flow rate per unit of the soil's TOTAL cross-sectional area, as though water were spread evenly across both the solid particles and the voids.
In reality, water can only travel through the void spaces between particles, so its actual average velocity through those spaces — the seepage velocity — must be higher than the discharge velocity, to carry the same total volume of flow through a smaller effective area (just the voids, not the whole cross-section).
| Velocity Type | Definition | Relationship |
|---|---|---|
| Discharge velocity (v) | Flow rate per unit TOTAL cross-sectional area (solids + voids) | v = K·i (direct from Darcy's law) |
| Seepage velocity (Vs) | Flow rate per unit VOID cross-sectional area only | Vs = v/n = v(1+e)/e |
Since porosity n is always a fraction less than 1, seepage velocity is always numerically larger than discharge velocity for the same flow — this is a purely geometric consequence of water only being able to travel through the (smaller) void portion of the soil's total cross-section.