Geotechnical·MCQ explained

Which of the following laboratory methods is more suitable to determine the permeability of less permeable soils?

Try it first: pick an option, then read the explanation.

Correct answer: D. Falling head test

Detailed Explanation

Choosing between the two standard laboratory permeability tests (see Q3's Going Deeper section) depends entirely on the soil's expected permeability range.

Why "Falling head test" Is Correct

The falling head test is the more suitable laboratory method for low-permeability soils, such as silt and clay. Because these soils allow only a very slow flow rate, a constant-head setup would take an impractically long time to produce a measurable discharge — the falling head test instead tracks a slowly falling water level over a convenient time interval, which remains measurable even at very low permeability.

Why the Other Options Are Wrong

  • Constant head test: specifically suited to HIGH-permeability soils (gravel, sand, see Q9) — using it on low-permeability soil would produce an immeasurably slow, impractical flow rate.
  • Confined flow pumping test: a field method for determining permeability of a confined aquifer over a large area (see Q21), not a standard laboratory test for a soil specimen.
  • Unconfined flow pumping test: similarly a field method for an unconfined aquifer (see Q20), not a laboratory method for testing a soil sample directly.

Key Point

Constant head → high permeability (sand, gravel); Falling head → low permeability (silt, clay) — this single pairing, and its reverse, is tested repeatedly across this topic (see Q9, Q15, Q18).

Key Concepts for Students

  • Both constant head and falling head are laboratory methods — contrast with pumping-in/pumping-out tests, which are field methods (see Q18, Q29).
  • See Q3, Q22, and Q24 for fully worked falling-head calculations.
  • The underlying reason for this soil-type/method pairing is purely practical: matching the test's sensitivity to the soil's actual flow rate.
  • See Q15 for the complete list of recognized laboratory methods, including two less commonly emphasized ones (capillarity-permeability test, and indirect determination from a consolidation test).

Going Deeper: Matching Test Method to Soil Permeability

Selecting the right permeability test isn't just a matter of convention — it reflects a genuine measurement limitation. A test method needs to produce a change (either a flow rate or a head drop) that's large enough to measure accurately within a reasonable time.

MethodFormulaBest Suited For
Constant headK = QL/(Aht)High-permeability soils (gravel, sand)
Falling (variable) headK = 2.303(aL/At)·log10(h1/h2)Low-permeability soils (silt, clay)

Attempting a constant-head test on clay would require an impractically long observation time to collect enough discharge to measure accurately; attempting a falling-head test on coarse sand would see the stand-pipe drain almost instantly, giving too little time resolution for an accurate reading. The two methods are complementary, each covering the permeability range where the other becomes impractical.