Table of Contents
Toggle
A transit theodolite is composed of several key components that work together to ensure precise angular measurements. The essential components of theodolite are :
1. Levelling Head
The levelling head is designed to perform three primary functions:
- Supporting the main parts of the theodolite.
- Attaching the theodolite securely to the tripod.
- Levelling the instrument accurately to ensure precise observations.
It is divided into two main parts:
Upper Tribrach
- The upper tribrach is constructed with three arms, each carrying a levelling screw. These levelling screws are essential for both supporting and leveling the theodolite.
- At the center of the upper tribrach, there is a female axis, which accommodates the lower male vertical axis of the theodolite, allowing for smooth and precise movement.
Lower Tribrach
- The lower tribrach has a circular hole at its center. This opening allows for a plumb bob to be suspended through it, enabling the quick and accurate centering of the instrument over a specific ground station point. Proper centering is crucial for maintaining the accuracy of angular measurements during surveying operations.
2. The Lower Plate (or Scale Plate)
The Lower Plate, also referred to as the Scale Plate, is a crucial component of a transit theodolite, attached to the outer spindle and featuring a horizontal graduated circle along its bevelled edge. This circle is graduated from 0° to 360°, with each degree further subdivided into ten-minute or twenty-minute arc intervals, allowing for precise angular measurements. The lower plate can be clamped in any desired position using a clamping screw, while a corresponding tangential (slow motion) screw enables fine adjustments, allowing for subtle corrections without altering the entire plate’s position.
When the lower clamp is tightened, the lower plate is securely fixed to the upper tribrach of the levelling head, ensuring the stability of the instrument during observations. The size of the theodolite is defined by the diameter of the lower plate, which typically ranges from 8 cm to 25 cm. For instance, a 13 cm theodolite signifies that the diameter of its lower plate measures 13 cm, directly impacting the instrument’s precision and readability. Thus, the lower plate, with its fine graduations and precision adjustments, serves as a foundational component, enabling accurate horizontal measurements and providing a stable base for precise angular observations.
3. The Upper Plate (or Vernier Plate)
The Upper Plate, also known as the Vernier Plate, is attached to the inner spindle axis of the theodolite. This plate is equipped with two verniers positioned diametrically opposite to each other, allowing for precise angular measurements. The upper plate is designed to overlap and protect the lower plate, fully covering the horizontal circle, except at the areas directly below the verniers, which are exposed for reading. To enhance visibility, the verniers are fitted with magnifiers, ensuring the accurate reading of smaller angular values.
Additionally, the upper plate supports the YS or AS, which provide bearings for the pivots of the telescope, ensuring smooth rotation and stability. It also features an upper clamp screw and a tangent (slow motion) screw, allowing the upper plate to be accurately clamped to the lower plate. When the upper clamp screw is engaged and the lower clamp is released, the instrument can be rotated around its outer spindle without any relative movement between the two plates.
Conversely, if the lower clamp screw is engaged and the upper clamp is released, the instrument rotates about its inner spindle, resulting in relative motion between the vernier and the graduated scale of the lower plate. This mechanism is crucial for measuring angles between two distinct settings of the instrument. It is essential to ensure that the clamping screws are properly tightened before utilizing the tangent screws for fine adjustments, as this prevents any unintended motion, allowing for precise alignment and measurement.
4. The Standards (or A Frame)
The Standards, also known as the A Frame, are a pair of rigid structures shaped like the English letter “A” and are firmly attached to the upper plate of the theodolite. These standards serve as bearings for the pivots of the telescope, providing crucial support and stability. The tops of the standards form the bearing surfaces, allowing the telescope to rotate freely around its horizontal axis in the vertical plane, enabling precise elevation and depression measurements.
The standards are designed to be sufficiently high to accommodate the full vertical rotation of the telescope without obstruction. Additionally, the T-frame and the arm of the vertical circle clamp are also securely attached to the standards, contributing to the structural integrity and operational functionality of the instrument. By providing a stable support system, the standards ensure that the telescope movements are smooth, allowing for accurate vertical and horizontal observations.
5. T-Frame or Index Bar
The T-Frame, also referred to as the Index Bar, is a T-shaped structure centered on the horizontal axis of the telescope within the frame of the vertical circle. The horizontal arm of this T-frame, known as the Index Arm, holds two verniers—C and D—positioned at its ends, which are used for reading vertical angles on the vertical circle.
The vertical leg of the T-frame is termed the Clipping Arm. It is equipped with a fork and two clamping screws at its lower extremity, providing secure attachment and stability. The index and clipping arms together form what is collectively known as the T-Frame.
At the top of the T-frame, a bubble tube is affixed, known as the Altitude Bubble Tube. This bubble tube is used for accurately leveling the instrument in the vertical plane, ensuring that all vertical measurements are taken from a properly leveled position. The T-frame’s precise construction and the placement of verniers and leveling aids make it essential for achieving accurate vertical observations during surveying tasks.
6. Plate Levels
The Plate Levels are precision components mounted on the upper plate of a theodolite to assist in leveling the instrument. Typically, there are two plate levels positioned at right angles to each other. One of these plate bubbles is aligned parallel to the trunnion axis, ensuring accurate leveling in one direction.
The plate levels are centered using the foot screws, which provide fine adjustments to achieve a perfectly leveled position. Proper leveling is crucial for ensuring that horizontal and vertical angle measurements are accurate and reliable. In some theodolite models, only a single plate level is provided, which is still sufficient for achieving the necessary leveling precision in most surveying applications.
7. Telescope
The Telescope is a critical component of the theodolite, enabling precise observations of distant objects. Telescopes used in theodolites are primarily classified into two types: the External Focussing Telescope and the Internal Focussing Telescope, each with unique structural features and advantages.
i. External Focussing Telescope
An External Focussing Telescope consists of two main tubes: the outer tube and the inner tube. The outer tube is fixed to the pivot using a sturdy metal band, while the inner tube slides within the outer tube using a rack and pinion mechanism. This mechanism is operated by turning a large milled-head screw, allowing the telescope to be focused on varying distances. Typically, the object glass is mounted at the end of the inner tube. While this type provides straightforward focusing, it can alter the overall length of the telescope, potentially affecting the instrument’s balance.
ii. Internal Focussing Telescope
The Internal Focussing Telescope employs a different design. It features an internal focussing lens, usually a double concave lens, positioned between the objective and the eyepiece, both of which are fixed at the ends of the main tube. Focusing is achieved by moving the internal focussing lens with a focussing screw. This design does not alter the overall length of the telescope during focusing, ensuring stability and balance.
Advantages of an Internal Focussing Telescope:
- The overall length of the telescope remains unchanged during focusing, which maintains the balance of the instrument.
- There is no risk of damaging the parallel plate bubble or compass glass cover underneath while transiting the telescope.
- The wear on the rack and pinion mechanism is reduced due to minimal movement of the internal lens.
- The line of collimation is minimally affected by focusing, ensuring higher accuracy.
- The telescope remains free from dust and moisture, enhancing durability and reliability.
- During tacheometric observations, the additive constant is generally eliminated, simplifying computations.
- The combined focal length of the internal lenses increases the telescope’s power, improving magnification.
- By incorporating a concave lens, the diameter of the objective can be increased without introducing aberrative effects, resulting in clearer and sharper images.
Thus, the internal focussing telescope is considered superior for most precision surveying tasks, offering enhanced stability, durability, and ease of use compared to the external focussing type.
8. Vertical Circle
The Vertical Circle is a crucial component of a theodolite, attached directly to the telescope and used to measure elevations and depressions. It is graduated in several different ways depending on the manufacturer. This allows for various methods of reading vertical angles in different configurations. The following are the three common graduation styles of the vertical circle:
i. Four-Quadrant Graduation: 0° to 90°
In this configuration, the vertical circle is divided into four quadrants, each reading from 0° to 90° in the same direction. The setup allows for easy measurement of elevations on one face of the theodolite and depressions on the other face. This makes it straightforward to switch between readings based on the telescope’s orientation.
ii.Four-Quadrant Graduation: 0° to 90° in Both Directions
In this style, the vertical circle is again divided into four quadrants, but the 0° mark is placed at the eyepiece end and the objective end, extending to 90° in both directions. The result is that elevations and depressions can be read symmetrically on both faces of the theodolite, making it versatile for readings without needing to switch face orientations.
iii. Full-Circle Graduation: 0° to 360°
In the full-circle configuration, the vertical circle is graduated from 0° to 360°. In this type, the zero point can be set at any position, allowing flexibility in taking measurements. To determine the true elevation or depression using this graduation style, the following rules are applied:
- If the difference between the greater and lesser readings is greater than 180°, the angle represents an elevation. To obtain the true elevation, subtract this value from 180° and divide by 2.
- If the difference is less than 180°, the angle indicates a depression. To determine the true depression, subtract this value from 180° and divide by 2.
9.Tripod
The Tripod serves as the foundational support structure for the theodolite during fieldwork, ensuring stability and accuracy of the instrument. It typically consists of three solid or framed legs, which provide a firm base for the theodolite, allowing for reliable observations. Each leg is equipped with pointed iron shoes at the lower ends, enabling them to be securely anchored into the ground, preventing any slippage or movement.
The tripod head is an essential part of the tripod assembly. It features an external screw on its upper surface, which is used to securely attach the foot plate of the levelling head. This connection ensures that the theodolite remains stable and accurately positioned during surveying operations. By maintaining the theodolite in a steady and level position, the tripod minimizes vibrations and disturbances, which is critical for precise angle measurements and readings.
10. Plumb Bob
he Plumb Bob is a simple yet crucial component of a theodolite, used for precise centering of the instrument over a ground station mark. It consists of a weighted pointed metal object suspended from a hook attached to the bottom of the main vertical axis. By aligning the plumb bob’s point directly above the station mark, surveyors can ensure that the theodolite is positioned accurately over the exact reference point, maintaining the vertical alignment of the instrument.